-40%

Rib in Box. RIBMN24Q4C Track Mount Style. 4 Output I/O Expander - a

$ 6.85

Availability: 100 in stock
  • Width: 6.560
  • Item Height: 4.940
  • Application: Commercial
  • All returns accepted: ReturnsNotAccepted
  • Item Length: 2.380
  • MPN: RIBMN24Q4C
  • Brand: RIB
  • Features: Track Mount
  • Length: 2.380
  • ItemPackageQuantity: 1
  • Condition: New – Open box

    Description

    Rib in Box. RIBMN24Q4C Track Mount Style. 4 Output I/O Expander. Condition is "NOT USED". Shipped with USPS Priority Mail.
    RIB
    Track Mount, 4 Output, Field Relay Module
    GRAINGER Item #
    244W96
    Mfr. Model #
    RIBMN24Q4C-PX
    JOHNSON CONTROLS
    Ribmn24Q4Cpx, Ribmn24Q4Cpx
    GRAINGER Item #
    42A370
    Mfr. Model #
    RIBMN24Q4C-PX
    # Relays & Contact Type: Expected Relay Life: Operating Temperature: Humidity Range: Power Status: Relay Status: Heartbeat Status: Dimensions: Track Mount: Approvals: Gold Flash: Override Switch:
    Four (4) SPDT Continuous Duty Coil
    10 million cycles minimum mechanical
    -30 to 140° F 5 to 95% (noncondensing)
    Green LED On = Power On
    Red LED On = Relay Activated
    Right-most decimal point 4.950˝ x 2.750˝ x 1.750˝
    MT212-6 Mounting Track Provided UL Listed, UL916, C-UL, CE,
    RoHS No No RIBMN24Q4C-PX 2.75˝ Track Mount 4 Output
    Field Adjustable Staging Threshold
    Relay Module with 24 Vac/dc Power and 0-10 Vdc Control Input Contact Ratings:
    15 Amp General Use @ 125 Vac
    10 Amp General Use @ 277 Vac
    10 Amp Resistive @ 30 Vdc (N/O)
    7 Amp Resistive @ 30 Vdc (N/C)
    1/2 HP @ 125 Vac
    1 HP @ 250 Vac
    1/4 HP @ 277 Vac 470 VA
    Pilot Duty @ 125 Vac 770 VA
    Pilot Duty @ 250 Vac Power
    Input: 24 Vac/dc ; 50-60 Hz 200mA max.
    Notes: •
    For AC applications, an isolation transformer, to be used solely for the power input, is recommended. •
    Relay will activate when control signal voltage reaches or exceeds individual relay ON point.
    Relay will deactivate when control voltage reaches or drops below individual OFF point. •
    Factory relay ON / OFF voltages: •
    Relay 1: 3V / 2.8V •
    Relay 2: 5V / 4.8V •
    R
    elay 3: 7V / 6.8V •
    Relay 4: 9V / 8.8 V •
    Minimum ON point: 0.5V •
    Maximum ON point: 9.9V •
    Minimum OFF point: 0.3V •
    Relay number will flash 3 times when voltage exceeds setpoint. •
    Pressing UP or DN button in normal run mode will display the voltage present on Analog Input. •
    ON/OFF points can be changed at any time, by the user, by entering “Program Mode” •
    User defined ON/OFF points will be maintained upon power loss.